Validez y confiabilidad de las escalas de comunicación y coordinación para medir rol interdependiente en enfermería
Validity and reliability of the communication and coordination scales to measure the inter-dependent nursing role
Validez e confiabilidade das escalas de comunicação e coordenação para mensurar o papel interdependente da enfermagem

Av. enferm; 28 (1), 2010
Publication year: 2010

Objetivo del estudio:

evaluar la validez y reproducibilidad de las escalas de Comunicación y Coordinación del instrumento ICU enfermera-médico diseñado por Shortell y colaboradores.

Métodos:

se realizó un estudio metodológico de validación de escalas mediante pruebas de validez facial y validez de contenido con panel de expertas. La muestra para la validez de constructo y consistencia interna fue de 295 enfermeras asistenciales y de 111 para la reproducibilidad prueba-reprueba.

Resultados:

el índice de aceptabilidad alcanzó el 100%; se obtuvo un índice de 0,82 para la escala de Comunicación en pertinencia y relevancia y para la escala de Coordinación 0,84 en la pertinencia y 0,88 en la relevancia. Se hallaron tres factores para ambas escalas. Se obtuvo un alfa de Cronbach de 0,92 para la Comunicación y 0,82 para la Coordinación; el coeficiente de correlación intraclase fue de 0,79 para Comunicación y de 0,63 para Coordinación.

Discusión:

el índice de validez facial fue similar a otros estudios y el de contenidos fue alto. Los factores hallados se mencionan en la literatura relacionada con aspectos de comunicación y coordinación. Los valores de alfa de Cronbach fueron superiores a los encontrados por otros investigadores, los Coeficientes de Correlacion Intraclase fueron excelentes y buenos.

Conclusiones:

los resultados muestran que el instrumento es válido, confiable y reproducible en el contexto colombiano, a partir de lo cual se recomienda su utilización para el estudio de la coordinación y comunicación como indicadores del rol interdependiente de enfermería.

Objective of the study:

To evaluate the validity and reproducibility of the Communication and Coordination scales of the nurse-doctor ICU instrument designed by Shortell et al.

Methods:

a scale validation methodological study was conducted through facial validity tests and content validity tests with an experts’ panel. The sample for constituting validity and internal consistency was of 295 in-class nurses and of 111 nurses for test-retest reproducibility.

Results:

The acceptance index reached 100%; an index of 0,82 was obtained in appropriateness and relevancy for the communication scale and 0,84 in appropriateness and 0,88 in relevancy for the coordination scale. Three factors were found for both scales. A Cronbach´s alpha of 0,92 was obtained for communication and 0,82 for Coordination; the inter-class correlation coefficient was 0,79 for Communication and 0,63 for Coordination respectively.

Discussion:

The facial validity index was similar to other studies and the content index was high. The factors found are mentioned in the communication and coordination aspects related literature. The Cronbach´s alpha values were higher than those found by other researchers; the Inter-class correlation coefficients were excellent and good.

Conclusions:

The results show that the instrument is valid, reliable and reproducible in the Colombian context, based on which it is recommended to use such instrument to study coordination and communication as indicators of the independent role of nursing.

Objetivo do estudo:

avaliar a validez e replicabilidade das escalas de Comunicação e Coordenação do instrumento ICU enfermeira-médico desenhado por Shortell e colaboradores.

Métodos:

Efetuou-se um estudo metodológico de validação de escalas mediante provas de validez facial e validez de contéudo com um painel de especialistas. A amostra para a validez de constructo e consistência interna foi de 295 enfermeiras assistênciais e de 11 para a replicabilidade prova-reprova.

Resultados:

o índice de aceptabilidade atingiu 100%; obteve-se um índice de 0,82 para a escala de Comunicação em pertinência e relevância e para a escala de Coordenação 0,84 na pertinência e 0,88 na relevância. Verificaram-se três fatores para ambas as escalas. Obteve-se um alfa de Cronbach de 0,92 para a Comunicação e 0,82 para a Coordenação; o coeficiente de correlação intraclasse foi de 0,79 para Comunicação e de 0,63 para Coordenação.

Discussão:

o índice de validez facial foi semelhante ao conseguido em outros estudos, enquanto o índice de contéudos foi alto. Os fatores verificados se mencionam na literatura relacionada com aspetos de comunicação e coordenação. Os valores de alfa de Cronbach foram superiores aos verificados por outros pesquisadores, os Coeficientes de Correlação Intraclasse foram excelentes e bons.

Conclusões:

os resultados evidenciam que o instrumento é válido, confíavel e replicável no contexto colombiano, assim sendo, recomenda-se sua utilização para o estudo da coordenação e comunicação como indicadores do papel interdependente da enfermagem.