Evaluación medioambiental de residuos hospitalarios peligrosos mediante luminometría y cultivos microbiológicos en una institución hospitalaria de Bogotá
Environmental assessment of hazardous hospital waste by luminometry and microbiological cultures in a hospital Bogota
Avaliação ambiental de resíduos hospitalares por luminometria e culturas microbiológicas em uma instituiçâo hospitalar de Bogotá

Rev. colomb. enferm; 12 (1), 2016
Publication year: 2016

Introducción:

el manejo adecuado de los residuos hospitalarios es un constante reto para la prevención en la propagación de infecciones y contaminación del medio ambiente.

Objetivo:

evaluar el manejo de residuos hospitalarios de riesgo infeccioso mediante luminometría de adenosín trifosfato (ATP) y cultivos microbiológicos en el Instituto del Corazón de Bucaramanga, sede Bogotá.

Materiales y métodos:

se realizó un estudio experimental de corte transversal prospectivo en el Instituto del Corazón de Bucaramanga, sede Bogotá en el periodo de agosto a diciembre de 2015; se aplicaron listas de verificación, medición de ATP y cultivos microbiológicos.

Resultados:

se encontraron diferencias estadísticamente significativas entre “Se cumple con la frecuencia y horarios establecidos para la recolección interna de residuos” (p valor= 0,001), “El tiempo de recolección de resi-duos dura entre 30–40 minutos” y “El personal encargado de la ruta sanitaria realiza higiene de manos al terminar el proceso” (p valor =0,005) respectivamente; para los otros ítems no se encontraron diferencias estadísticamente significativas (Valor p>0,005), solo una muestra cumplía el estándar (Cumplimiento ≤25 Unidades Relativas de luz (URL), y en el aislamiento microbiológico se evidenció el crecimiento de un Hongo Filamentoso.

Conclusión:

es necesario estandarizar el procedimiento de limpieza en super-ficies ambientales y monitorizar el proceso de ruta sanitaria de residuos peligrosos en la institución.

Introduction:

proper hospital waste management represents a constant challenge to preventing the spread of infection and contamination of the environment.

Objective:

to evaluate the proper management of hospital waste that represents an infec-tious risk by means of adenosine triphosphate luminometry (ATP) and microbiological cultures in the Heart Institute Bucaramanga - Bogotá.

Materials and methods:

an experimental prospective cross-sectional study was conducted at the Heart Institute of Bucaramanga - Bogotá from August to December 2015. Verification lists, ATP measurement and microbiological cultures were applied.

Results:

- there were statistically signi-ficant differences between “the frequency and schedules for internal garbage collection are maintained” (p value = 0.011), “Does the waste collection time lasts between 30-40 minutes?” and “Does the staff responsible for health route performs hand hygiene at the end of the process?” (p value = 0.005 respec-tively); the other items were not statistically significant (p value > 0.005), and only one sample met the standard (Compliance ≤ 25 Relative Light Units (URL), and in the microbiological isola-tion a filamentous fungus growth was evident.

Conclusion:

it is necessary to standardize the cleaning procedure of surfaces and monitor the process of safe handling of hazardous waste in the institution.

Introdução:

o manuseio adequado dos resíduos hospitalares é um desafio constante para a prevenção da propagação de infecções e da contaminação do meio ambiente.

Objetivo:

avaliar o manejo de resíduos hospitalares de risco infeccioso por luminometria de trifosfato de adenosina (ATP) e culturas micro-biológicas no Instituto do Coração de Bucaramanga, unidade Bogotá.

Materiais e métodos:

um estudo experimental de corte transversal prospectivo foi realizado no Instituto do Coração Bucaramanga – unidade Bogotá, no período de agosto a dezembro de 2015, onde foram aplicadas listas de verificação, medição de ATP e culturas microbiológicas.

Resultados:

foram encontradas diferenças estatisticamente significativas entre “Foram cumpridos a frequência e os horários estabelecidos para a coleta interna de resíduos”, (valor p= 0,001), “O tempo de coleta de resíduos dura entre 30 a 40 minutos?” e “O pessoal responsável pela rota sanitária higieniza as mãos no fim do processo?” (valor p =0,005), respectivamente; para os demais itens não foram encontradas diferenças estatisticamente significativas (Valor p>0,005), apenas uma amostra atendia ao padrão (Cumprimento <25 Unidades Relativas de Luz (URL) e no isolamento microbiológico, o crescimento de um fungo filamentoso foi evidenciado.

Conclusão:

é necessário padro-nizar o procedimento de limpeza em superfícies ambientais e monitorar o processo de rota sanitária de resíduos perigosos na instituição.