Deterioro de la piel asociado con aseguramiento del dispositivo de acceso intravascular
Skin breakdown associated with securing of the intravascular access device
Ruptura da pele associada à fixação do dispositivo de acesso intravascular

Rev. cienc. cuidad; 19 (2), 2022
Publication year: 2022

El deterioro de la piel asociado con adhesivos de uso médico en dispositivos de acceso intra-vascular es un evento adverso que puede contribuir a la interrupción de la terapia de infusión intravascular. La Sociedad de enfermeras de infusión recomienda usar tecnologías de protec-ción como apósito estéril para aseguramiento del catéter y cinta quirúrgica para aseguramien-to complementario.

Objetivo:

Analizar las causas y prevalencia del deterioro de la piel aso-ciado con aseguramiento del dispositivo de acceso intravascular.

Métodos:

Estudio analítico, de corte transversal. Para recolectar datos se empleó un formato digital y observación directa a pacientes hospitalizados (n=813) con algún dispositivo de aseguramiento en acceso intra-vascular central o periférico, y aseguramiento complementario con cinta quirúrgica, dando seguimiento durante 7 días en febrero 2020.

Resultados:

El deterioro de la piel incluyó de-sprendimiento de epidermis, maceración, dermatitis irritativa por contacto y alérgica, con prevalencia de 2.2%. Se atribuyeron a catéter venoso central (f=8), catéter venoso periférico (f=7) y cinta quirúrgica para aseguramiento complementario del apósito transparente (f=3).

Discusión:

Las causas de deterioro de la piel se debieron al tipo de dispositivo y material implementado para aseguramiento; en la mayoría de casos las lesiones se encontraron en accesos venosos periféricos, seguida de accesos venosos centrales, siendo el aseguramiento complementario la menor causa de deterioro de la piel.

Conclusiones:

La técnica correcta de aplicación y retiro de insumos adhesivos de estabilización y aseguramiento del catéter intravascular evitará el desprendimiento de los mismos, lesiones de piel e interrupción de la terapia de infusión intravascular
Deterioration of the skin associated with medical adhesives in intravascular access devices is an adverse event that can contribute to the discontinuation of intravascular infusion ther-apy. The Society of Infusion Nurses recommends the use of protective technologies such as sterile dressing for catheter securing and surgical tape for supplemental securing.

Objective:

To analyze the causes and prevalence of skin deterioration associated with securing the intravascular access device.

Methods:

Analytical, cross-sectional study. To collect data, a digital format and direct observation of hospitalized patients (n = 813) were used with some device for securing in central or peripheral intravascular access, and complementary securing with surgical tape, with follow-up for 7 days in February 2020.

Results:

The Skin deterioration included epidermal detachment, maceration, irritant contact and allergic dermatitis, with a prevalence of 2.2%. They were attributed to central venous catheter (f = 8), peripheral venous catheter (f = 7) and surgical tape for complementary securing of the transparent dressing (f = 3).

Discussion:

The causes of skin deterioration were due to the type of device and mate-rial implemented for belaying; In the majority of cases, the lesions were found in peripheral venous accesses, followed by central venous accesses, with supplementary insurance being the least cause of skin deterioration.

Conclusions:

The correct technique for applying and removing adhesive supplies for stabilization and securing of the intravascular catheter will avoid their detachment, skin lesions and interruption of intravascular infusion therapy
A deterioração da pele associada a adesivos médicos em dispositivos de acesso intravascular é um evento adverso que pode contribuir para a descontinuação da terapia de infusão intra-vascular. A Society of Infusion Nurses recomenda o uso de tecnologias de proteção, como curativo estéril para fixação do cateter e esparadrapo para fixação suplementar.

Objetivo:

Analisar as causas e a prevalência da deterioração da pele associada à fixação do dispositivo de acesso intravascular.

Métodos:

Estudo analítico, transversal. Para a coleta de dados, uti-lizou-se o formato digital e observação direta dos pacientes internados (n = 813) com algum dispositivo de fixação em acesso intravascular central ou periférico e a fixação complementar com esparadrapo, com seguimento de 7 dias em fevereiro de 2020.

Resultados:

A deterio-ração da pele incluiu descolamento epidérmico, maceração, contato com irritante e dermatite alérgica, com prevalência de 2,2%. Foram atribuídos a cateter venoso central (f = 8), cateter venoso periférico (f = 7) e esparadrapo para fixação complementar do curativo transparente (f = 3).

Discussão:

As causas da deterioração da pele foram devido ao tipo de dispositivo e material implementado para amarração; Na maioria dos casos, as lesões foram encontradas em acessos venosos periféricos, seguidos de acessos venosos centrais, sendo a amarração suplementar a menor causa de deterioração da pele.

Conclusões:

A técnica correta de apli-cação e retirada de suprimentos adesivos para estabilização e fixação do cateter intravascular evitará seu descolamento, lesões cutâneas e interrupção da terapia de infusão intravascular