Cuidados de Enfermería en la Monitorización de la Tensión Arterial Media (TAM): Inserción, Mantenimiento y Retirada
Nursing Care in Mean Arterial Pressure (MAP) Monitoring: Insertion, Maintenance, and Removal
Cuidados de Enfermagem na Monitorização da Pressão Arterial Média (PAM): Inserção, Manutenção e Retirada

Notas enferm. (Córdoba); 26 (45), 2025
Publication year: 2025

En el contexto de la Unidad de Cuidados Intensivos (UCI), donde ingresan pacientes con gran inestabilidad hemodinámica y potencial riesgo de fallo multiorgánico, la monitorización de la presión arterial invasiva cobra relevancia. Estos pacientes, que a menudo requieren estancias prolongadas en la UCI, demandan un control exhaustivo y continuo de sus parámetros vitales, sien-do la presión arterial uno de los pilares fundamentales para la toma de decisiones. La monitorización de la presión arterial invasiva proporciona información precisa y continua sobre la presión arterial, permitiendo evaluar el rendimiento cardíaco y la perfusión tisular; se considera el método de referencia (patrón de oro) para medir la presión arterial, se realiza mediante la inserción de un catéter arterial en una arteria, comúnmente la radial, conectándolo a un transductor y monitor. En la inserción del catéter arterial, requiere personal médico altamente capacitado, teniendo en cuenta que existen dos métodos:- utilizando referencias anatómicas y palpación del pulso radial para la localización del vaso y- por eco guiada. La estandarización de los procedimientos y la formación continua del personal de enfermería son fundamentales para garantizar la seguridad y eficacia de la monitorización invasiva de la presión arterial.(AU)
In the context of the Intensive Care Unit (ICU), where patients with great hemodynamic instability and potential risk of multiple organ failure are admitted, invasive blood pressure monitoring becomes even more relevant. These patients, who often require prolonged stays in the ICU, demand exhaustive and continuous monitoring of their vital parameters, with blood pressure being one of the fundamental pillars for decision making.Invasive blood pressure monitoring provides accurate and continuous information on blood pressure, allowing evaluation of cardiac performance and tissue perfusion; It is considered the reference method (gold standard) for measuring blood pressure. It is performed by inserting an arterial catheter into an artery, commonly the radial artery, connecting it to a transducer and monitor. In the insertion of the arterial catheter, a complex procedure that requires highly trained medical personnel, there are two methods, using anatomical references and palpation of the radial pulse to locate the vessel and using ultrasound guidance.Standardization of procedures and continuous training of nur-sing staff are essential to ensure the safety and effectiveness of invasive blood pressure monitoring. (AU)
No contexto da Unidade de Terapia Intensiva (UTI), onde são admitidos pacientes com grande instabilidade hemodinâmica e potencial risco de falência de múltiplos órgãos, a monitorização invasiva da pressão arterial torna-se ainda mais relevante. Esses pacientes, que muitas vezes necessitam de permanência prolongada em UTI, demandam monitoramento exaustivo e contínuo de seus parâmetros vitais, sendo a pressão arterial um dos pilares fundamentais para a tomada de decisão. A monitorização invasiva da pressão arterial fornece informações precisas e contínuas sobre a pressão arterial, permitindo avaliação do desempenho cardíaco e da perfusão tecidual; É considerado método de referência (padrão ouro) para aferição da pressão arterial. É realizado através da inserção de um cateter arterial em uma artéria, comumente a artéria radial, conectando-o a um transdutor e monitor. Na inserção do cateter arterial, procedimento complexo que requer pessoal médico altamente treinado, existem dois métodos, utilizando referências anatômicas e palpação do pulso radial para localização do vaso e utilizando orientação ultrassonográfica. A padronização de procedimentos e a capacitação contínua da equipe de enfermagem são essenciais para garantir a segurança e a eficácia da monitorização invasiva da pressão arterial. (AU)