Validation of the Comply with Post-Exposure Management Among Health Care Workers Instrument for Brazil
Validación para Brasil del Comply with Post-Exposure Management Among Health Care Workers
Validação para o Brasil do Comply with Post-Exposure Management Among Health Care Workers

Rev. Esc. Enferm. USP; 50 (6), 2016
Publication year: 2016

Abstract OBJECTIVE To validate the Comply with post-exposure management among healthcare workersinstrument for Nursing in Brazil. METHOD A methodological study carried out with 137 nursing professionals exposed to biological material. The existence of floor and ceiling effects was analyzed, evaluating reliability by the internal consistency of the items and test-retest reproducibility. The construct validity was analyzed by the multitrait-multi method analysis. RESULTS Ceiling effects were found in two subscales. The result of the internal consistency of four subscales varied between 0.81 and 0.91. The results were considered satisfactory, while two subscales presented an unsatisfactory result (0.50 and 0.37). An evaluation of the measurement stability obtained positive results in relation to the statistical significance, with Intraclass Correlation Coefficient values between the two measurements ranging from 0.301 to 0.727; the validity of a convergent and divergent construct was confirmed by multitrait-multi method analysis, except for the Attitude subscale, which presented unsatisfactory values. CONCLUSION The instrument presents satisfactory results for validity and reliability, except for the Attitude dimension.
Resumen OBJETIVO Validaren Brasil el instrumentoComply with post-exposure management among health care workers para la enfermería. MÉTODO Estudio metodológico realizado con 137 profesionales de enfermería expuestos a material biológico. Se analizó la existencia de los efectos floor y ceilingy se valoró la fidedignidad por la consistencia interna de los ítems y la estabilidad de la medida (test-retest). Se analizó la validez de constructo por medio del análisis multibrazo-multimétodo. RESULTADO Se verificaronefectos ceiling en dos subescalas. El resultado de la consistencia interna, de cuatro subescalas, varió entre 0,81 y 0,91, resultados considerados satisfactorios, y dos subescalas presentaron resultado insatisfactorio (0,50 y 0,37). La evaluación de la estabilidad de la medida obtuvo resultados positivos con relación a la significación estadística, con valores del Coeficiente de Correlación Intraclase, entre ambas medidas, variando de 0,301 a 0,727; se confirmó la validez de constructo convergente y divergente mediante el análisis multibrazo-multimétodo, excepto la subescala Actitud, la que presentó valores insatisfactorios. CONCLUSIÓN Elinstrumento presenta resultados satisfactorios de validez y fidedignidad, excluyéndose la dimensión Actitud.
Resumo OBJETIVO Validar para o Brasil o instrumento Comply with post-exposure management among health care workers para a enfermagem. MÉTODO Estudo metodológico realizado com 137 profissionais de enfermagem expostos a material biológico. Analisou-se a existência dos efeitos floor e ceiling e avaliou-se a fidedignidade pela consistência interna dos itens e estabilidade da medida (teste-reteste). Analisou-se a validade de construto por meio da análise multitraço-multimétodo. RESULTADOS Verificaram-se efeitos ceiling em duas subescalas. O resultado da consistência interna, de quatro subescalas, variou entre 0,81 e 0,91, resultados considerados satisfatórios, e duas subescalas apresentaram resultado insatisfatório (0,50 e 0,37). A avaliação da estabilidade da medida obteve resultados positivos em relação à significância estatística, com valores do Coeficiente de Correlação Intraclasse, entre as duas medidas, variando de 0,301 a 0,727; confirmou-se a validade de construto convergente e divergente por meio da análise multitraço-multimétodo, exceto a subescala Atitude, que apresentou valores insatisfatórios. CONCLUSÃO O instrumento apresenta resultados satisfatórios de validade e fidedignidade, excluindo-se a dimensão Atitude.